<?xml version="1.0" encoding="UTF-8"?>
<!DOCTYPE article PUBLIC "-//NLM//DTD JATS (Z39.96) Journal Publishing DTD v1.3 20210610//EN" "JATS-journalpublishing1-3.dtd">
<article article-type="research-article" dtd-version="1.3" xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink" xmlns:xsi="http://www.w3.org/2001/XMLSchema-instance" xml:lang="ru"><front><journal-meta><journal-id journal-id-type="publisher-id">emcardio</journal-id><journal-title-group><journal-title xml:lang="ru">Неотложная кардиология и кардиоваскулярные риски</journal-title><trans-title-group xml:lang="en"><trans-title>Emergency Cardiology and Cardiovascular Risks journal</trans-title></trans-title-group></journal-title-group><issn pub-type="ppub">2616-633X</issn><publisher><publisher-name>Белорусский государственный медицинский университет</publisher-name></publisher></journal-meta><article-meta><article-id pub-id-type="doi">10.51922/2616-633X.2022.6.1.1442</article-id><article-id custom-type="elpub" pub-id-type="custom">emcardio-100</article-id><article-categories><subj-group subj-group-type="heading"><subject>Research Article</subject></subj-group><subj-group subj-group-type="section-heading" xml:lang="ru"><subject>Оригинальные научные публикации</subject></subj-group><subj-group subj-group-type="section-heading" xml:lang="en"><subject>Original Scientific Research</subject></subj-group></article-categories><title-group><article-title>Сравнение гемодинамических параметров и отдаленного прогноза у пациентов после аортального протезирования искусственными клапанами сердца «Планикс-Э» и зарубежными аналогами</article-title><trans-title-group xml:lang="en"><trans-title>Comparison of hemodynamic parameters and long-term prognosis in patients after aortic valve replacement using Planiks-E and foreign equivalents</trans-title></trans-title-group></title-group><contrib-group><contrib contrib-type="author" corresp="yes"><name-alternatives><name name-style="eastern" xml:lang="ru"><surname>Андралойть</surname><given-names>И. Е.</given-names></name><name name-style="western" xml:lang="en"><surname>Andraloits</surname><given-names>I.</given-names></name></name-alternatives><bio xml:lang="ru"><p>220036, г. Минск, ул. Р. Люксембург 110</p></bio><xref ref-type="aff" rid="aff-1"/></contrib></contrib-group><aff-alternatives id="aff-1"><aff xml:lang="ru"><institution>РНПЦ «Кардиология»</institution></aff><aff xml:lang="en"><institution>Republican Scientific and Practical Center “Cardiology”</institution></aff></aff-alternatives><pub-date pub-type="collection"><year>2022</year></pub-date><pub-date pub-type="epub"><day>27</day><month>06</month><year>2025</year></pub-date><volume>6</volume><issue>1</issue><fpage>1442</fpage><lpage>1447</lpage><permissions><copyright-statement>Copyright &amp;#x00A9; Андралойть И.Е., 2025</copyright-statement><copyright-year>2025</copyright-year><copyright-holder xml:lang="ru">Андралойть И.Е.</copyright-holder><copyright-holder xml:lang="en">Andraloits I.</copyright-holder><license xml:lang="ru" license-type="creative-commons-attribution" xlink:href="https://creativecommons.org/licenses/by/4.0/" xlink:type="simple"><license-p>Данная работа распространяется под лицензией Creative Commons Attribution 4.0.</license-p></license><license xml:lang="en" license-type="creative-commons-attribution" xlink:href="https://creativecommons.org/licenses/by/4.0/" xlink:type="simple"><license-p>This work is licensed under a Creative Commons Attribution 4.0 License.</license-p></license></permissions><self-uri xlink:href="https://emcardio.bsmu.by/jour/article/view/100">https://emcardio.bsmu.by/jour/article/view/100</self-uri><abstract><p>В данной статье представлены ближайшие и отдаленные результаты протезирования аортального клапана искусственными двустворчатыми протезами клапанов сердца 422 пациентам. Для протезирования использовались искусственные клапаны сердца (ИКС) Планикс-Э, МедИнж-2, Carbomedics, ATS Medtronic, St. Jude Medical с посадочными размерами 19, 21 и 23 мм. Проанализированы госпитальные и отдаленные результаты непосредственно в зависимости от применяемого типа-размера ИКС. Отмечается достоверное снижение пикового и среднего трансклапанного градиента на всех аортальных протезах (p &lt; 0,0015), а также увеличение эффективной площади открытия (ЭПО) аортального клапана. ЭПО протеза «Планикс Э» достоверно не отличалась от зарубежных аналогов для каждого типоразмера. ЭПО протезов St. Jude Medical была достоверно больше с сравнении с протезами Sorin Carbomedics (р &gt; 0,005). Пиковый градиент протезов достоверно отличался между собой для различных типов ИКС (p = 0,007). Наибольший максимальный трансклапанный градиент был на протезах Sorin Carbomedics. Средний градиент давления достоверно отличался между протезами (p &lt; 0,05). Феномен «протез-пациент несоответствие» (ППН) умеренной степени в послеоперационном периоде наблюдался у 30,3% пациентов, тяжелой степени – 4,1 %. У пациентов, которым были имплантированы протезы «Планикс-Э», феномен ППН тяжелой степени наблюдался у 3,2 % пациентов, что достоверно не отличалось от зарубежных аналогов. ППН умеренной степени встречался реже всего на протезах «Планикс-Э» и ATS Medtronic (в 27,80 и 28,60 % соответственно). Общая госпитальная летальность составила 3,4%. Риск развития умеренного ППН составил 1,66 (95% ДИ 1,087 – 2,539, р = 0,19). Медиана среднего периода наблюдения составила 3,4 (2,12÷5,93) года. Достоверных различий 3- и 5-летней выживаемости между пациентами с развитием или без развития феномена «протез-пациент несоответствия» выявлено не было (log-rank test, р = 0,539). Среди ИКС «Планикс-Э» пятилетняя выживаемость составила 87%. Феномен ППН достоверно не влиял на отдаленную выживаемость. Аортальные протезы «Планикс-Э» не уступают по гемодинамическим показателям аналогичным зарубежным протезам, при этом риск развития умеренного ППН достоверно меньше.</p></abstract><trans-abstract xml:lang="en"><p>The article presents the results of aortic valve replacement with artificial prosthetic heart valves. The study comprised 422 patients after aortic valve replacement with mechanical bicuspid valve prostheses of 19, 21, and 23 mm. The valves used were «Planiks-E», MedIng-2, Carbomedics, ATS Medtronic, St. Jude Medical. Hospital and long-term results are analyzed directly depending on the type-size of the AMHV used. There was a significant decrease in the peak and average transvalvular gradient on the all aortic valves (p &lt; 0.0015), as well as an increase in the effective orifice area (EOA) of the aortic valve. EOA of the prosthesis “Planiks E” was not significantly different from that of its foreign equivalents. The EOA of St.Jude Medical prostheses was significantly larger compared to the Sorin Carbomedics prostheses (p &gt; 0.005). The peak and mean gradients were different significantly (p = 0.007 and p &lt; 0.05). The highest maximum systolic gradient was observed with Sorin Carbomedics prostheses. The phenomenon of prosthesis-patient mismatch of moderate degree in the early postoperative period was observed in 30.3% of patients, and in 4.1% it was severe. For “Planiks-E” prostheses, severe PPM was observed in 3.2% of patients. “Planiks-E” and ATS Medtronic prostheses were less common related to moderate PPM, in 27.80% and 28.60% correspondently. Overall hospital mortality was 3.4%. The risk of developing moderate PPN was 1.66 (95% CI 1.087 – 2.539, p = 0.19). The follow-up period mediana was 3.4 (2.12÷5.93) years. There were no significant differences in survival between patients without or with different PPM degrees (log-rank test, p = 0.539). Among “Planiks-E” the five-year survival rate was 87%.The PPN phenomenon did not significantly affect long-term survival. The heart valve prosthesis “Planiks-E” is comparable in its hemodynamic parameters to similar imported prostheses, the risk of moderate PPN being significantly lower.</p></trans-abstract><kwd-group xml:lang="ru"><kwd>протезы клапанов сердца</kwd><kwd>Планикс-Э</kwd><kwd>St. Jude</kwd><kwd>МедИнж-2</kwd><kwd>протезирование аортального клапана</kwd><kwd>феномен «протез-пациент несоответствие»</kwd></kwd-group><kwd-group xml:lang="en"><kwd>artificial heart valves</kwd><kwd>“Planiks-E”</kwd><kwd>aortic valve replacement</kwd><kwd>St.Jude Medical</kwd><kwd>MedIng-2</kwd><kwd>“prosthesis-patient mismatch” phenomenon</kwd></kwd-group></article-meta></front><back><ref-list><title>References</title><ref id="cit1"><label>1</label><citation-alternatives><mixed-citation xml:lang="ru">Lancellotti P, Pibarot P, Chambers J. et al. (2016) Recommendations for the imaging assessment of prosthetic heart valves: a report from the European Association of Cardiovascular Imaging endorsed by the Chinese Society of Echocardiography, the Inter-American Society of Echocardiography and the Brazilian Department of Cardiovascular Imaging. Eur Heart J Cardiovasc Imaging? , vol. 17, pp. 589–90.</mixed-citation><mixed-citation xml:lang="en">Lancellotti P, Pibarot P, Chambers J. et al. (2016) Recommendations for the imaging assessment of prosthetic heart valves: a report from the European Association of Cardiovascular Imaging endorsed by the Chinese Society of Echocardiography, the Inter-American Society of Echocardiography and the Brazilian Department of Cardiovascular Imaging. Eur Heart J Cardiovasc Imaging? , vol. 17, pp. 589–90.</mixed-citation></citation-alternatives></ref><ref id="cit2"><label>2</label><citation-alternatives><mixed-citation xml:lang="ru">Rahimtoola SH. The problem of valve prosthesis-patient mismatch. Circulation.1978;58:20-4.</mixed-citation><mixed-citation xml:lang="en">Rahimtoola SH. The problem of valve prosthesis-patient mismatch. Circulation.1978;58:20-4.</mixed-citation></citation-alternatives></ref><ref id="cit3"><label>3</label><citation-alternatives><mixed-citation xml:lang="ru">Barner H. B., Labovitz A. J., Fiore A. C. (1994) Prosthetic valves for the small aortic root. J. Card. Surg, vol. 9, pp. 154–157.</mixed-citation><mixed-citation xml:lang="en">Barner H. B., Labovitz A. J., Fiore A. C. (1994) Prosthetic valves for the small aortic root. J. Card. Surg, vol. 9, pp. 154–157.</mixed-citation></citation-alternatives></ref><ref id="cit4"><label>4</label><citation-alternatives><mixed-citation xml:lang="ru">Blais C., Dumesnil J. G., Baillot R. et al. (2003) Impact of valve prosthesispatient mismatch on short-term mortality after aortic valve replacement. Circulation, vol. 108, pp. 983–988.</mixed-citation><mixed-citation xml:lang="en">Blais C., Dumesnil J. G., Baillot R. et al. (2003) Impact of valve prosthesispatient mismatch on short-term mortality after aortic valve replacement. Circulation, vol. 108, pp. 983–988.</mixed-citation></citation-alternatives></ref><ref id="cit5"><label>5</label><citation-alternatives><mixed-citation xml:lang="ru">Bleiziffer S., Eichinger W. B., Hettich I. et al. (2007) Prediction of valve prosthesis-patient mismatch prior to aortic valve replacement: which is the best method? Heart, vol. 93, pp. 615–620.</mixed-citation><mixed-citation xml:lang="en">Bleiziffer S., Eichinger W. B., Hettich I. et al. (2007) Prediction of valve prosthesis-patient mismatch prior to aortic valve replacement: which is the best method? Heart, vol. 93, pp. 615–620.</mixed-citation></citation-alternatives></ref></ref-list><fn-group><fn fn-type="conflict"><p>The authors declare that there are no conflicts of interest present.</p></fn></fn-group></back></article>
